CHEVRON ENVIRONMENTAL HEALTH CENTER -- CHEVRON ATF DEXRON -- 9150-00-657-4959
=====================  Product Identification  =====================

Product ID:CHEVRON ATF DEXRON
MSDS Date:04/08/1993
FSC:9150
NIIN:00-657-4959
=== Responsible Party ===
Company Name:CHEVRON ENVIRONMENTAL HEALTH CENTER
Address:15299 SAN PABLO AVE.
Box:4054
City:RICHMOND
State:CA
ZIP:94804-0054
Country:US
Info Phone Num:800-582-3835
Emergency Phone Num:415-233-3737 OR 800-321-0623
CAGE:0AHD1
=== Contractor Identification ===
Company Name:CHEVRON ENVIRONMENTAL HEALTH CENTER INC
Address:15299 SAN PABLO AVE
Box:4054
City:RICHMOND
State:CA
ZIP:94804
Country:US
Phone:800-582-3835
CAGE:0AHD1

=============  Composition/Information on Ingredients  =============

Ingred Name:THE FOLLOWING CAS NUMBERS WERE LISTED BY THE MFR ON THE
    MSDS W/O %. ALL ARE CLAIMED TO BE NON-CARCINOGENIC IN THE MSDS.
RTECS #:9999999ZZ
Other REC Limits:.

Ingred Name:HYDROTREATED HEAVY NAPHTHENIC DISTILLATE, PETROLEUM
CAS:64742-52-5
RTECS #:PY8035000
Other REC Limits:NONE RECOMMENDED

Ingred Name:MINERAL OIL
CAS:64742-53-6
RTECS #:PY8036000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)

Ingred Name:DISTILLATES,HYDROTREATED,HEAVY PARAFFINIC
CAS:64742-54-7
RTECS #:PY8035500
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)

Ingred Name:SOLVENT DEWAXED RESIDUAL OIL (PETROLEUM)
CAS:64742-62-7
Other REC Limits:NONE RECOMMENDED

Ingred Name:MINERAL OIL
CAS:64742-65-0
RTECS #:PY8038500
Other REC Limits:NONE RECOMMENDED

Ingred Name:HYDROTREATED C25 BRIGHT STOCK BASED LUBRICATING OIL
CAS:72623-83-7
Other REC Limits:NONE RECOMMENDED

Ingred Name:SOLVENT REFINED HYDROTREATED RESIDUAL OIL
CAS:64742-57-0
Other REC Limits:NONE RECOMMENDED

Ingred Name:ADDITIVES
Fraction by Wt: <15%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:BASED ON DATA FROM SIMILAR MATERIALS,
    THIS DEXRON ATF IS EXPECTED BY CHEVRON TO BE PRACTICALLY NON-TOXIC
    AND NOT TO CAUSE SIGNIFICANT IRRITATION TO BODY TISSUES.
Explanation of Carcinogenicity:MFR STATES THAT PRODUCT IS SEVERELY
    REFINED AND IS NOT LISTED BY IARC, NTP OR OSHA AS A CARCINOGEN.
Effects of Overexposure:EYES:POSSIBLE MILD IRRITATION. SKIN:POSSIBLE
    MILD IRRIT/DEFATTING. INHALED: POSSIBLE RESPIRATORY IRRITATION.
    INGEST:NO ACUTE SYSTEMIC EFFECTS (PER MFR).
Medical Cond Aggravated by Exposure:NO EFFECTS EXPECTED

=======================  First Aid Measures  =======================

First Aid:EYE:FLUSH W/WATER 15 MIN. SKIN:WASH W/SOAP & WATER.
    INHALED:NO EXPECTED TO BE A PROBLEM, NO FIRST AID REQUIRED.
    INGESTED:GIVE MILK OR WATER TO DRINK. CONSULT MEDICAL PERSONNEL
    BEFORE INDUCING VOMITING . IF UNABLE TO CONSULT MEDICAL PERSONNEL,
    TRANSPORT TO A HOSPITAL WITH THE CONTAINER.

=====================  Fire Fighting Measures  =====================

Flash Point:320F,160C
Extinguishing Media:CO2,DRY CHEMICAL,ALCOHOL FOAM,WATER FOG
Fire Fighting Procedures:FOR FIRES ENVOLVING THIS MATERIAL, DO NOT
    ENTEER ANY ENCLOSED OR CONFINED SPACE W/O PROTECTIVE EQUIPMENT
    INCLUDING SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NO INFORMATION GIVEN ON MSDS BY MFR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE PROPER PERSONAL PROTECTION. STOP THE
    SOURCE OF THE LEAK OR RELEASE. USE ABSORBENT MATERIAL AND RECOVER
    FOR PROPER DISPOSAL. REPORT AS REQUIRED OF AN OIL SPILL.
Neutralizing Agent:NONE

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL, DRY AND WELL VENTILATED
    AREA. KEEP AWAY FROM HEAT AND OPEN FLAMES.KEEP CONTAINER CLOSED
    WHEN NOT IN USE.
Other Precautions:'EMPTY' CONTAINERS MAY CONTAIN RESIDUE OR VAPOR.
    TREAT THEM WITH THE RESPECT DUE FULL ONES. DO NOT CUT,WELD,ETC. ON
    THEM.  DO NOT USE PRESSURE TO EMPTY CONTAINER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:RESPIRATOR WILL NOT NORMALLY BE NECESSARY.  USE
    NIOSH/MSHA APPROVED AIR SUPPLIED RESPIRATOR OR RESPIRATOR FOR OIL
    MIST IF EXPOSURE IS ABOVE THE TLV/PEL. SEE 29 CFR 1910.134 FOR
    REGULATIONS PERTAINING  TO RESPIRATOR USE.
Ventilation:USE ADEQUATE VENTILATION, (GENERAL OR LOCAL EXHAUST) TO
    MAINTAIN EXPOSURES BELOW THE PEL/TLV.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES OR CHEM SPLASH GOGGLES
Other Protective Equipment:NO SPECIAL SKIN PROTECION REQUIED.  AVOID
    PROLONGED/REPEATED SKIN CONTACT.
Work Hygienic Practices:MFR: ?	HMIS:USE GOOD INDUSTRIAL HYGIENE
    PRACTICE. AVOID UNNECESSARY CONTACT. WASH THOROUGHLY BEFORE EATING
    OR DRINKING.
Supplemental Safety and Health
KEY2:KT  MSDS OBTAINED TO FULFILL A TECH SUPPORT REQEST.

==================  Physical/Chemical Properties  ==================

HCC:V6
NRC/State Lic Num:NONE
Spec Gravity:0.89
Solubility in Water:INSOLUBLE
Appearance and Odor:RED LIQUID

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING MATERIALS SUCH AS CHLORATES, NITRATES, PEROXIDES.
Stability Condition to Avoid:NO DATA AVAILABLE
Hazardous Decomposition Products:NORMAL COMBUSTION FORMS CO2,WATER
    VAPOR, AND OXIDES OF SULFUR,N,P. INCOMPLETE COMBUSTION PRODUCES
    CARBON MONOXIDE
Conditions to Avoid Polymerization:WILL NOT OCCUR

====================  Disposal Considerations  ====================

Waste Disposal Methods:REP9ORT AND DISPOSE OF COLLECTED MATERIAL IN
    ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.