===================== Product Identification ===================== Product ID:AIR DUSTER MSDS Date:06/14/1991 FSC:6850 NIIN:00N056736 === Responsible Party === Company Name:TERAND INDUSTRIES INC Box:9947 City:FT LAUDERDALE State:FL ZIP:33310 Country:US Info Phone Num:305-974-5440 Emergency Phone Num:305-974-5440 CAGE:OO296 === Contractor Identification === Company Name:TERAND INDUSTRIES, INC. Box:9947 City:FT. LAUNDERDALE State:FL ZIP:33310 Phone:305-974-5440 CAGE:OO296 ============= Composition/Information on Ingredients ============= Ingred Name:METHANE, CHLORODIFLUORO-; (CHLORODIFLUOROMETHANE) (SARA 313) (CERCLA) CAS:75-45-6 RTECS #:PA6390000 Fraction by Wt: 100% OSHA PEL:1000 PPM ACGIH TLV:1000 PPM Ozone Depleting Chemical:2 Ingred Name:SUPP DATA:FLUORIDES OR PHOSGENE . RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:INHAL:MINIMAL EFT <1000 PPM; DIZZ, DROWS & THROAT IRRIT AT LEVELS >1000 PPM. SKIN:CONT W/LIQ MAY CAUSE FROSTBITE. INGEST:SLIGHTLY TOX, INGEST OF LG QTYS MAY CAUSE DROW & LOSS OF CONSCIOUSNESS, STOM CR AMPS, PAIN, NAUS, VOMIT & DIARR. EYES:CAN CAUSE SLIGHT TO MOD IRRIT W/POSS CORNEAL INJURY. INTENTIONAL (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ:MISUSE BY DELIB CONC & INHAL CONTENTS CAN BE HARMFUL/FATAL. CHLOROFLUOROCARBON (CFC) MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. AD RENOMIMETICS (I.E., EPINEPHRINE) MAY BECONTRA-INDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY/ (SUPP DATA) Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:INGEST:CALL MD IMMEDIATELY . EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES, LIFTING UPPER & LOWER LIDS. GET MEDICAL ATTENTION. SKIN:WASH EXPOSED AREAS W/SOAP & WATER. TREAT FOR FROSTBITE IF NECESSA RY. INHAL:REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT, ADMINISTER OXYGEN. IF BREATHING STOPS GIVE ARTIFICIAL RESPIRATION. GET MEDICAL ATTENTION. ===================== Fire Fighting Measures ===================== Flash Point Method:TOC Flash Point:NONE Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE. Fire Fighting Procedures:USE NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL PROT EQUIP . KEEP CNTNRS COOL. USE EQUIP/SHIELDING REQD TO PROT PERS AGAINST BURSTING, RUPTURING/ (SUPDAT) Unusual Fire/Explosion Hazard:NFPA 30B CODE:LEVEL 1 AEROSOL. AT ELEVATED TEMPS (>120F) CNTNRS MAY VENT, RUPTURE/BURST. THERMAL DECOMP PRODS MAY INCL FLUORIDES, CHLORIDES & PHOSGENE . ================== Accidental Release Measures ================== Spill Release Procedures:CLEAN UP AREA BY MOPPING OR W/ABSORBENT MATERIALS & PLACE IN CLOSED CONTAINERS FOR DISPOSAL. CONTACT FEDERAL, STATE OR LOCAL AUTHORITIES FOR APPROVED DISPOSAL PROCEDURES. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:DO NOT STORE AT TEMPS >120F. AEROSOL PRODS PRESENT LTD HAZ DURING STOR/USE IF LBL PRECS ARE FOLLOWED. Other Precautions:PRESSURIZED CNTNRS MUST NOT BE EXPOS TO TEMPS >120F & SPRAY SHOULD NOT BE DIRECTED TOWARD FACE/EYES, OPEN FLAME/OTHER SOURCE OF IGNIT. PLEASE READ & FOLLOW DIRECTIONS ON PROD LBL; THEY ARE YOUR BEST G UIDE TO USING THIS PROD IN MOST (SUPDAT) ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NIOSH/MSHA APPROVED ORGANIC VAPOR TYPE RESPIRATOR ACCEPTABLE IF CONCENTRATION IS >1000 PPM. Ventilation:DO NOT USE IN CONFINED SPACES. Protective Gloves:VITON, PVC & PVA GLOVES. Eye Protection:ANSI APPRVD CHEMICAL SPLASH GOGG . Other Protective Equipment:NO SPECIFIC PROTECTION REQUIRED. Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE IN WORK AREA. WASH HANDS BEFORE EATING. Supplemental Safety and Health VP:125 PSIG @ 77F. FIRE FIGHT PROC:VENTING CNTNRS. EFTS OF OVEREXP:CHRONICALLY EXPOS TO CFC'S . OTHER PREC:EFTIVE WAY & THEY ALSO GIVE NEC SFTY PRECS TO PROT YOUR HLTH. NO SMOKING IN AREA OF USE . DO NOT USE IN GEN VICIN OF ARC WELDING, OPEN FLAMES/HOT SURFS. HEAT &/OR UV RADIA MAY CAUSE FORM OF CHLORIDES, (ING 2) ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:-41F,-40C Vapor Pres:SUPP DATA Vapor Density:3.03 Spec Gravity:1.2 (H*2O=1) Solubility in Water:0.3% @ 77F Appearance and Odor:SLIGHT ETHEREAL ODOR. Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES ALKALI METALS, ALKALINE EARTH METALS, POWDERED ALUMINUM, BERYLIUM, ZINC, ETC. Stability Condition to Avoid:DO NOT EXPOSE TO OPEN FLAMES OR TO TEMPERATURES >120F. Hazardous Decomposition Products:HYDROCHLORIC & HYDROFLUORIC ACIDS & POSSIBLY CARBONYL HALIDES. CHLORIDES, FLUORIDES & PHOSGENE . ==================== Disposal Considerations ==================== Waste Disposal Methods:WHEN USED PROPERLY AEROSOL PRODUCTS DO NOT GENERATE HAZ WASTE. EMPTY DE-PRESSURIZED CNTNRS CAN NOT BE REUSED & SHOULD BE WRAPPED & PUT IN PERMITTED WASTE MANAGEMENT FACILITY. CONSULT FEDERAL, STATE & LOCAL DISP AUTHS FOR APPROVED PROCEDURES. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.